HyperVibes indicators are deterministic PineScript-subset programs evaluated against server-fetched, closed Hyperliquid candles. They produce research evidence and cannot place orders.

Definitions, versions, and runs​

An indicator definition owns its name, enabled state, selected Analysis instruments, and one to eight explicit timeframes. Timeframes are normalized, unique, and ordered by duration. One source version and one input-value set apply to every configured timeframe; create separate definitions when inputs must differ by timeframe. Multiple configured timeframes are independent runs, not Pine request.security calls.

Every source change creates an immutable version. A run snapshots one version, instrument, timeframe, and canonical closed-candle boundary. Its durable identity is (version, instrument, timeframe, boundary), so results from different candle series cannot collide. Creating or updating an enabled definition immediately queues the active version at the latest closed boundary for every configured timeframe and selected instrument. The scheduler then reconciles only the latest boundary; it does not backfill downtime.

For example, a definition targeting BTC with 15m, 1h, and 4h creates three independent BTC targets. At 12:00 UTC their canonical boundaries are all 12:00, but at 12:15 only the 15m target advances. Charts and result reads require a timeframe and never combine those series.

Analysis dependencies​

Each Analysis run persists its applicable indicator set before dispatch. For an Analysis boundary B, every indicator timeframe uses its greatest canonical close at or before B. Thus Analysis at 10:15, 10:30, and 10:45 can all reuse the same 1h run at 10:00; Analysis at 11:00 uses the 11:00 run. Definition, version, instrument, timeframe, boundary, and run ID remain frozen even if the indicator configuration changes later. A set is limited to 1,024 dependencies.

The persisted deadline is not reset by a restart. At the deadline, queued or running dependencies freeze as timed_out; later completion does not make them visible to that Analysis credential. In-process completion notifications reduce latency, while database polling remains the restart and multi-process fallback.

Execution and retries​

Indicator workers use leased, token-fenced claims. A stale worker cannot write after another attempt owns its run. Retryable infrastructure and temporary market-data failures use persisted exponential backoff and make at most three attempts. Invalid timeframes, source or input errors, compilation/runtime failures, non-finite output, and result-size violations are terminal.

Successful runs retain the exact bounded candle input, numeric plots, visual marker data, latest values, and diagnostics used for the result.

The agent-facing MCP contracts use schema_version=2. Discovery returns a lightweight items envelope with total, offset, returned_count, and next_offset (default limit=20). Items contain definition identity, name, enabled/archived state, timeframes, active version ID, and a compact latest_run header. Discovery excludes archived definitions. Each header represents only one instrument/timeframe, not all targets; Analysis must inspect its applicable frozen target set explicitly.

Result reads return one run by default, its exact provenance/status, latest numeric values, compact diagnostics, the latest 20 aligned bars, and the newest 20 marker events. bar_limit and marker_limit accept 1–100 as maximum requested counts. Complete calls (including multiple runs) are fitted to 24 KiB UTF-8 text and 1,000 lines by reducing complete bars/events. budget_reduced reports fitting; actual returned counts and cursors describe coverage. An oversized minimum representation produces an actionable bounded error rather than an empty, non-advancing page or silently fewer runs.

Numeric and marker pagination are independent. Every continuation supplies the first page's exact run_id, instrument and timeframe:

  • For forward numeric history, start with bar_start=0, then follow next_bar_start. bar_index is absolute, oldest-first.
  • For backward history, begin with the default latest page, then pass bar_end=previous_bar_end. This exclusive-end cursor preserves gap-free coverage even when subsequent page sizes shrink. Do not combine bar_start and bar_end. previous_bar_start remains a start-range hint; use previous_bar_end for backward traversal.
  • For marker history, follow next_marker_start. Events are ordered by source candle descending, then original event_position ascending for same-candle events. The marker page does not follow the numeric page's range.

Compact markers retain source bar_index, opened_at, kind, title, text/character where applicable, value and visual offset, without chart styling. opened_at is the source candle's open time, not its close/confirmation time; visual offset never changes the observed event time. bar_count and marker_count describe entire histories; bar_returned_count and marker_returned_count describe the page. bars_complete and markers_complete are true only if the page contains the entire available respective history. Available empty marker history has count zero and is complete. Unavailable evidence has evidence_available=false, null total counts, and false completeness flags. A missing run returns an empty list. Failed/skipped runs retain status and error information. Diagnostic/error abbreviation is explicit in diagnostics_abbreviated/error_summary_abbreviated; full diagnostics remain in the HTTP representation.

A partial page cannot establish absence of signals across the entire history. If OpenCode unexpectedly reports truncation, retry smaller authorized MCP pages and record the coverage limitation; never follow the global output-cache filesystem path. The HTTP API and operator charts expose complete immutable stored series. Analysis is instructed to cite exact frozen run IDs and the relevant numeric values and marker times in its research memories so later reviews can retrieve the same evidence instead of substituting a newer indicator run.

At reconciliation cadence, structured debug logging reports ready depth, oldest ready age, running and retry counts, and frozen timed-out dependency count.

Configuration​

  • INDICATOR_MAX_CONCURRENT_EXECUTIONS optionally sets 1..=32 workers per application process. Without it, HyperVibes uses one less than the detected logical CPU count, with a minimum of 1 and maximum of 32. Multi-replica deployments must divide host capacity explicitly.
  • INDICATOR_ANALYSIS_WAIT_TIMEOUT_SECONDS accepts 1..=300 and defaults to 30 seconds. It is persisted per Analysis dependency set; unfinished work is frozen as timed_out and remains unavailable to that dispatch.

Definitions are archived rather than deleted so immutable runs can remain historical evidence. Retention never removes a run referenced by an Analysis dependency. Review and Chat may request a historical result by exact run_id; Analysis credentials can read only succeeded, failed, or skipped runs in their own frozen dependency set.

The operator UI supports the same one-to-eight timeframe contract as the JSON API and MCP tools. The API uses only the plural timeframes field for definition mutations.